Products

Mantacc 93051 Saliva Collection Stick

The Mantacc 93051 saliva collection stick can be used to collect saliva samples for a variety of testing purposes like DNA, RNA, cortisol and THC.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES
Mantacc 93051 Saliva Collection Stick

Product Features

The Mantacc 93051 Saliva Collection Stick has a PVA sponge tip on a PS handle, with a total length of 84mm and a 21mm long sponge head. The medical grade PVA sponge has an ultra high liquid absorption ratio.
  • Non-invasive saliva collection in 30-60s
  • Suitable for COVID-19 testing
  • Enables self-collection at home
  • Simple, fast, accurate and reliable
Applications
Use a Mantacc 93051 saliva stick to easily collect saliva for various IVD testings:
  • DNA testing
    The inert sponge material does not interfere with downstream DNA extraction and amplification, allowing high-quality DNA to be recovered from saliva.
  • RNA testing
    The PVA sponge protects RNA in saliva from degradation during collection and transport to the lab. Intact RNA can then be purified for sensitive molecular testing.
  • Drugs testing
    The absorbent sponge tip rapidly collects sufficient saliva volume needed for screening tests for illicit drugs like THC.
  • Hormone tesing
    With accurate, reproducible cortisol testing, it is easy to monitor patients’ hormone levels and adrenal function via saliva.
Saliva Collection Vs Blood Collection In DNA Test
Saliva Blood
✅Non-invasive collection ❌Invasive Collection
✅Simple to use ❌Disliked by donors
✅No need for trained personnel ❌Trained phlebotomist required
✅Shorter collection time ❌Longer collection time
✅No need for dry ice ❌Requires dry ice
✅No electricity needed ❌Freezer costs can reach US$7000
✅Samples stable for years at room temperature ❌Power outage can result in unusable samples
SPECIFICATIONS

Model 93051
Tip Material PVA sponge
Tip Length 0.83’’ (21mm)
Tip Diameter 0.49'' (12.5mm)
Handle Material PS plastic
Total Length 3.31‘’ (84mm)
Sterilization EO
Stimulant additive No citric acid (optionally added)

Model Total Length (mm) Tip Length (mm) Tip Width (mm) Tip/Handle Material
93051 84±2 21±1 12.5±1 PVA Sponge/PS Plastic
93052 100±5 13±1 8.5±1 PVA Sponge/PS Plastic
93053 73±2 10±1 12.5±1 PVA Sponge/PS Plastic
93054 95±2 21±1 14±1 PVA Sponge/PS Plastic
93055 85±2 10±1 13.5±1 PVA Sponge/PS Plastic

Mantacc 93051-93055 Saliva Collection Stick specification structure display

PACKAGING
Packaging Details 1 kit/box, 170 boxes/carton
The Case Dimension 47cm*30cm*47cm
Pallet Size 24 cartons/ pallet
Delivery Time

≤10,000 3 working days

≤100,000 7 working days
≤1,000,000 15 working days
≥1,000,000 Please contact us
INSTRUCTIONS

[Instructions for use]

1) Models other than 93051, 93052, 93053, 93054, 93055 model:
a) Peel apart the sterile package.
b) Hold the handle and place the sampling swab into the mouth for sampling.
c) Rotate the sampling swab gently 3-5 times, and then slowly take out.
d) Place the swab into the sample collection tube, break it at the break point (if

applicable), and then store it to complete the sampling.

2) For 93051, 93052, 93053, 93054, 93055 model:
a) Peel apart the sterile package.
b) Hold the handle and place the sampling swab on the inner wall of the mouth and the
upper surface of the tongue.
c) Keep it for at least 2 minutes until it is full of saliva, soft and swelling, and then take it

out to complete the sample collection.

[Contraindication]

If any irritation or allergic reaction occurs, please stop use and ask a doctor.

 

[Warnings]

1) This is a single-use product, don’t reuse it.
2) Keep away from flames or sparks.
3) Keep out of the reach of children.
4) Avoid soaking swabs with preservation solution before sampling.
5) Avoid repeated freezing-thawing.
6) If any damage of package, please do not use it.
7) If it is expired, please do not use it.
8) If you are allergic to sponge and plastic material, please do not use it.
9) Please do not eat, smoke or drink 30 minutes before sampling, to avoid affecting the sampling effect.

10) The used products should be treated according to local medical waste regulations, and cannot be disposed of carelessly.

 

[Precautions and Notes]

  • 1. Do not use the kit beyond the expiration date printed on the pouch.
  • 2. To ensure the purity of the target sample, gargle with warm water at least 30 minutes before sampling to remove any residual food particles from your mouth.
  • 3. If sampling is due to start in 30 minutes, refrain from eating, drinking, smoking, or chewing gum to prevent interference with the saliva sample.
  • 4. To minimize invasive bacteria in the air, perform the sampling process in a clean location and complete it as quickly as possible.